Skip to content

For biotech and API manufacturers

Long recipes, tight ranges, every step on recipe.

Long recipes and tight ranges leave little room for a skipped step or a value off its range. Typed capture and section gates keep execution on the recipe, and scheduled runs compare parameters batch over batch.

How it works
B-2411-068 · execution1 for review

Batch B-2411-068 · Section 6 of 14

Each value checked against its range as it is typed

STEPPARAMETERRANGEENTEREDSTATUS
6.1Charge temperature20–25 °C22.4 °CSigned
6.2pH adjust6.8–7.27.0Signed
6.3Reaction hold4.0–4.5 h4.6 hReview
6.4Section gate: QA sign-offrequired—Locked
Numbers carry ranges
Each value is checked against its range as it is typed.
Gated by section
A step cannot be skipped; locked sections stay visible.
Compared batch over batch
A slow rise toward a limit shows before it becomes a deviation.

Typed capture

Every value checked against its range as it is typed.

Numbers carry units and ranges, and validation runs at entry, save and publish. A value outside its range is set aside for review.

  • Values captured at execution, against the cell they were defined for
  • Numbers carry units and ranges
  • Validation runs at entry, save and publish
B-2411-068 · 143 ENTRIES1 to review

Green: within limits, cleared on entry. Red: outside its limit, set aside for QA.

ENTRY 4.3 · DRY TO LOD

0 %limit 2.5 %2.7 %

Section gates

A long recipe, followed in order.

Gates block movement until conditions pass, and locked sections stay visible. Every signature records the signer, the time and what it means.

  • A step cannot be skipped
  • Gates block movement until conditions pass
  • Locked sections stay visible
SECTION 3 · DISPENSINGAll values in range, signedComplete
SECTION 4 · GRANULATIONWaiting for the section gateQA sign-off on section 3 opens this section
SECTION 5 · COMPRESSIONLocked, still visible

Watch and Foresee

A slow rise shows before it becomes a deviation.

On each scheduled run, parameters, yields and cycle times are compared batch over batch. A value creeping toward its limit is flagged with the batches behind it.

  • Compared batch over batch
  • Flagged with the batches as evidence
  • Sent to the lead who owns the line
GRANULATOR 2 · LOD % · LAST 12 BATCHESRising

Five batches in a row above the one before. Flagged on the Friday run, with the batches as evidence.

How it works

From a long recipe to a batch on its ranges

  1. 01Recipe writtenThe master formula sets the range for every value.
  2. 02QA approvesQA approves the recipe before anyone can use it.
  3. 03Gated by sectionEach section stays locked until its conditions pass.
  4. 04Checked as typedEach value is checked against its range and signed.
  5. 05Compared batch over batchScheduled runs flag a slow rise toward a limit.

What changes

The week before, and the week after.

TODAY

  • Reviewers check every page of the paper record, line by line
  • Missing or wrong entries go back to the floor for correction
  • The trend was visible days before anyone saw it
  • Calibration and training dates kept in a spreadsheet

WITH SYNNGULAR

  • Typed capture checks each value against its range at entry
  • Gates block movement until conditions pass
  • Foresee flags a parameter rising toward its limit across batches
  • Records can only reference what is qualified

For biotech and API plants

Built for long recipes and tight ranges

  • MFR authoringStructured sections and tables, validated on save and publish.
  • Gated batch executionTyped capture and section gates on the floor.
  • e-SignaturesSigner, date, time and meaning recorded with every signature.
  • WatchBatches, yields, and cycle times, compared run to run.
  • ForeseeEarly warnings with their evidence attached.
  • Approvals and qualificationsRole-bound stages and qualification tracking.

Scope your first workflow against your plant

Bring one product and one workflow. We scope the pilot against your plant.