Skip to content

Synngular eBMR

Every batch entry checked and signed as it is made.

Masters, MFR authoring, staged approvals and gated execution, every change audited. Write the master formula once, get QA's approval, and run the batch step by step until it is ready for release.

How it works
MFR-PCM-500 v4.2Effective

Paracetamol 500 mg · Granulation

Section 4 of 9 · approved by QA · every value has its limit

STEPPARAMETERLIMITENTERED
4.1Dispense lactose12.40 ± 0.05 kg12.41 kgSigned
4.2Impeller speed140–160 rpm150 rpmSigned
4.3Dry to LOD≤ 2.5 %2.1 %Signed
4.4Section gate: QA sign-offrequired—Locked
Checked at entry
Each value is checked against its limit as it is typed.
Gated by section
A step cannot be skipped; locked sections stay visible.
Every change audited
Every draft, signature and release, per record.

MFR authoring

Author once, reuse everywhere, see every change.

Sections come from a managed template library, and parameters are validated on save and on publish. Reviewers see what changed, version to version.

  • Sections drawn from a managed template library
  • Parameters validated on save and on publish
  • Reviewers see the change, version to version
MFR-PCM-500 · DRAFT v4.32 changes
PARAMETERv4.2v4.3
Impeller speed140–160 rpm140–160 rpm
Granulate hold time36 h48 h
Dry to LOD≤ 3.0 %≤ 2.5 %
Blocked on saveStep 4.5 has a value with no range. Add a limit to publish.

Staged approvals

Nothing goes effective until the right people sign.

Role-bound review and qualification before a version goes effective. Every signature records the signer, the time and what it means.

  • Role-bound stages, in a fixed order
  • Qualification tracking on people and equipment
  • Records can only reference what is qualified
MFR-PCM-500 v4.3 · APPROVAL
  1. ✓DraftedProduction authorSigned
  2. ✓ReviewedProduction headSigned
  3. 3QA approvalQA lead · meaning: approved for useWaiting
  4. 4EffectiveVersion can be used on the floorLocked

Gated execution

The floor follows the recipe, step by step.

Typed capture on the floor, section gates and e-signatures. Gates block movement until conditions pass, and locked sections stay visible.

  • Values captured at execution, against the cell they were defined for
  • Gates block movement until conditions pass
  • Numbers carry units and ranges
SECTION 3 · DISPENSINGAll values in range, signedComplete
SECTION 4 · GRANULATIONWaiting for the section gateQA sign-off on section 3 opens this section
SECTION 5 · COMPRESSIONLocked, still visible

How it works

From master formula to released batch

  1. 01Recipe writtenThe master formula is written once, with the limit for every value.
  2. 02QA approvesQA approves the recipe before anyone can use it.
  3. 03Made on the floorOperators follow it step by step. A step cannot be skipped.
  4. 04Checked and signedEach value is checked against its limit and signed.
  5. 05Batch releasedThe record is complete, so QA releases the batch.

What changes

The week before, and the week after.

TODAY

  • MFRs copied from the last product and edited by hand
  • Each tech transfer re-typed into a new format
  • Reviewers can't see what changed between versions
  • Calibration and training dates kept in a spreadsheet

WITH SYNNGULAR EBMR

  • Sections drawn from a managed template library
  • Parameters validated on save and on publish
  • Reviewers see the change, version to version
  • Qualification status lives on the equipment and people masters

What's in eBMR

Everything eBMR does, in one place.

  • MastersProducts, materials, equipment, people, and locations.
  • MFR authoringStructured sections and tables, validated on save and publish.
  • Templates and librariesManaged section library and clean-copy inserts.
  • Approvals and qualificationsRole-bound stages and qualification tracking.
  • Gated batch executionTyped capture and section gates on the floor.
  • Audit trailEvery draft, change, and approval, per record.

See eBMR on your own batch.

Bring one product and one workflow. We scope the pilot against your plant.