Skip to content

For quality teams

Review the exceptions, close the CAPA, sign the release.

Entries within their limits clear on their own, so QA reviews only the exceptions before release. Deviations and CAPA are logged against the batch, and each record's audit trail is current when the auditor asks.

How it works
QA review · plant 11 exception

QA review queue · PCM-500

Entries within their limits cleared on their own · sample

ITEMWHATLINKED TOSTATUS
B-2411-068Dry to LOD, 4.3line 2Review
DEV-0412Deviation, evidence attachedB-2411-068Open
CAPA-0091Tracked to closureDEV-0412In progress
B-2411-067142 entries within limitsline 2Cleared
Review by exception
Reviewers see exceptions and what changed, not every line.
Deviations on the record
Logged against the batch, evidence attached.
Ready for the audit
One audit trail per record, always current.

Review by exception

QA reads the one entry that needs a look.

Typed capture checks each value against its range at entry. What stays inside its limits clears on its own; only what falls outside reaches the reviewer.

  • Each value checked against its range at entry
  • Reviewers see exceptions and what changed
  • Release readiness reported to QA leads every Monday
B-2411-068 · 143 ENTRIES1 to review

Green: within limits, cleared on entry. Red: outside its limit, set aside for QA.

ENTRY 4.3 · DRY TO LOD

0 %limit 2.5 %2.7 %

Deviation and CAPA

From the deviation to closure, in the same system.

Foresee flags a parameter rising toward its limit across batches. Deviations are logged against the batch record with their evidence, and CAPA is tracked to closure.

  • Foresee flags a slow rise before it becomes a deviation
  • Deviations logged against the batch record, evidence attached
  • CAPA tracked to closure in the same system
DEV-0412 → CAPA-0091
  1. ✓Deviation loggedAgainst B-2411-068, entry 4.3, evidence attachedDone
  2. ✓InvestigationDryer service record and LOD historyDone
  3. 3CAPADrying time restored, operators retrainedIn progress
  4. 4ClosureEffectiveness check signed by QAOpen

Audits and product review

Walk into the audit already ready.

Each record carries its own audit trail, always current. Ask pulls the evidence for an audit, and every answer names the records it came from.

  • One audit trail per record, always current
  • Ask pulls the evidence, with its sources
  • Inspection packets assembled on request
ASK

Which batches used lactose lot L-2209?

ANSWER

Three batches, all released. None has an open deviation.

B-2411-061ReleasedMES
B-2411-064ReleasedMES
B-2411-066ReleasedERP

How it works

A batch through QA, start to finish

  1. 01Checked as typedEach entry is checked against its limit as it is typed.
  2. 02One needs a lookOnly the entry outside its limit is set aside.
  3. 03Deviation loggedIf it needs one, the deviation is logged against the batch.
  4. 04QA decidesQA reviews that entry and signs with a reason.
  5. 05ReleasedEverything else was clear, so the batch is released.

What changes

The week before, and the week after.

TODAY

  • Reviewers check every page of the paper record, line by line
  • Investigation data pulled from four systems by hand
  • CAPA tracked in a spreadsheet nobody owns
  • Auditor requests answered by searching the archive

WITH SYNNGULAR

  • Reviewers see exceptions and what changed, not every line
  • Deviations logged against the batch record, evidence attached
  • CAPA tracked to closure in the same system
  • Ask pulls the evidence, with its sources

What quality teams use

Review, investigate and release in one place

  • Review by exceptionOnly entries outside their limits reach the reviewer.
  • Deviation and CAPADeviations logged against the record, CAPA to closure.
  • e-SignaturesSigner, date, time and meaning recorded with every signature.
  • Audit trailEvery draft, change, and approval, per record.
  • ForeseeEarly warnings with their evidence attached.
  • ReportDigests on a schedule, like release readiness every Monday for QA leads.

600+

QA hours redeployed a year in Morepen's deviation and CAPA engagement.Figures measured and reported by Morepen.

Read the case study

See it with your QA team.

Bring one product and one workflow. We scope the pilot against your plant.